Enthalpy auto-interpolated from steam table
Flash Steam Heat Exchanger
Steam Conditions
MPa
kJ/kg
kJ/kg
MPa
kJ/kg
kJ/kg
°C
Flow & Cooling Water
T/H
°C
°C
°C
W/(m²·°C)
Results
kg/h
%
(h₁−h₂)/(h₂s−h₂) × 100
kW
qmi · (h₁s − h₂) / 3600
°C
T₁ − t̀c;₁
°C
T₁ − t̀c;₂
m²
Q / (K · LMTD)
Reference: Saturated Steam Table (by Pressure)
| P (MPa) | T sat (°C) | h' (kJ/kg) | h'' (kJ/kg) |
|---|---|---|---|
| 0.001 | 6.95 | 29.2 | 2513.3 |
| 0.01 | 45.80 | 191.8 | 2583.7 |
| 0.05 | 81.34 | 340.6 | 2645.3 |
| 0.1 | 99.63 | 417.5 | 2675.1 |
| 0.2 | 120.24 | 504.8 | 2706.5 |
| 0.5 | 151.87 | 640.4 | 2748.6 |
| 1.0 | 179.92 | 762.8 | 2777.7 |
| 2.0 | 212.42 | 908.6 | 2798.7 |
| 4.0 | 250.39 | 1087.2 | 2800.5 |
| 6.0 | 275.63 | 1213.3 | 2783.8 |
| 10.0 | 311.04 | 1407.2 | 2724.5 |
| 14.0 | 336.71 | 1570.4 | 2637.1 |
| 20.0 | 365.79 | 1827.2 | 2413.1 |